BM-503 Multi-Parameter Patient Monitor
|
|
|
|
Feature set
- 12.1" color TFT LCD screen with maximum 8-waveform display;
- Rechargeable high-energy built-in battery;
- Advanced streamlined outline design;
- Portable, compact, lightweight;
- Operating menu with multi-language interface selection (English, Spanish, Portuguese, Chinese, French, etc.);
- Easy operation with user-friendly menu structure design and rotary dial;
- Against electrosurgical interference and defibrillation (no need to disconnect the monitor from the patient while in the process of defibrillation);
- WAN communication function to network with central monitoring system and make long--distance monitoring, diagnosis, maintenance and software upgrade possible;
- Optional built-in wireless networking function;
- External printer support to record graph and trend;
- Intelligent and comprehensive audiovisual alarm;
- In-hospital applications include emergency and pre- and post-operative care, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas;
- Suitable for use in physician's offices, clinics, outpatient surgical centers, extended care facilities, and other patient care areas which require affordable monitoring.
|
|
Technical Specification |
|
 |
|
| Standard Configuration |
ECG, HR, PR, SpO2, ST analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2 (surface and rectal type), Drug dose calculation |
| Optional Configuration |
Wireless connection, recorder, and ETCO2, 2-IBP |
| Non-invasive blood pressure |
• Measurement Type: adult, pediatric, neonate
• Measurement Range:
• systolic (4.0 - 27.0 kPa),
• diastolic (1.3 - 33.0 kPa),
• mean (2.6 - 35.0 kPa)
• Accuracy: ± 0.4 kPa or 5%
• Resolution: 0.1 kPa
• Protection: Over pressure |
| ECG |
• Input: 5 wires ECG cable
• Lead section: I, II, III / aVR, aVL, aVF/V
• Gain (mm/mV): 1/4, 1/2, 1, 2, 4
• Frequency Response:
• diagnosis (0.05 - 100Hz),
• monitor (0.5 - 40Hz),
• surgery (1.0 - 25 Hz)
• Sweep Speed (mm/sec): 12.5, 25, 50
• Heart Rate Range: 30-254 bpm
• Heart Rate Accuracy: ± 1%
• ST Segment Deviation Analysis: -8.0 ± 0.8 mV
• ST Accuracy: ± 0.02 mV
• Invasive BP Range: 0 ~ 40 kPa (0 ~ 300 mmHg)
• Channel: 2 channel
• Transducer Sensitivity: 5 mV/B/mmHg
• Unit display: kPa or mmHg selectable |
| Temperature |
• Measurement Range: 25-45゚C
• Accuracy: ± 0.1゚C
• Resolution: 0.1゚C
• Response Time: ≤ 3 min. |
| Respiration Rate |
• Measurement Range: 0-120 bpm (adult)
• Accuracy: ± 1 bpm or 5%
• Resolution: 1 bpm |
| CO2 |
• Measurement Range: 0-120 bpm (adult)
• Accuracy: ± 1 bpm or 5%
• Resolution: 1 bpm |
| Pulse Oximetry |
• SpO2 Measurement Range: 0-100%
• Resolution: 1%
• Pulse Measurement Range: 30-254 bpm
• Accuracy: ± 2%
• Resolution: 1 bpm |
| Environment |
• Temperature for Operation: 0.5-40゚C
• Relative Humidity for Operation: ≤ 80%
• Temperature for Storage: -20-50゚C
• Relative Humidity for Storage: ≤ 90% |
| Power Requirements |
• Input: 98~260V AC, 50/60Hz
• Consumption: ≤ 80VA |
| Safety Standard |
IEC 60601-1 |
| Quality System |
ISO13485: 2003 |
|
|
|
|
|